{"id":817,"date":"2026-11-27T07:45:06","date_gmt":"2026-11-27T07:45:06","guid":{"rendered":"https:\/\/www.kalibracepipet.cz\/?p=817"},"modified":"2026-11-27T07:45:07","modified_gmt":"2026-11-27T07:45:07","slug":"dekontaminace-pipet-pomoci-nuvaclean-a-jeji-vyznam-pro-spolehlive-vysledky","status":"publish","type":"post","link":"https:\/\/www.kalibracepipet.cz\/?p=817","title":{"rendered":"Dekontaminace pipet pomoc\u00ed nUVaClean\u2122 a jej\u00ed v\u00fdznam pro spolehliv\u00e9 v\u00fdsledky"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">V\u00fdm\u011bna \u0161pi\u010dky po ka\u017ed\u00e9m vzorku pat\u0159\u00ed k z\u00e1klad\u016fm spr\u00e1vn\u00e9ho pipetov\u00e1n\u00ed. Kontaminace se v\u0161ak m\u016f\u017ee zachytit i na samotn\u00e9 pipet\u011b, nap\u0159\u00edklad na ku\u017eelu pro nasazen\u00ed \u0161pi\u010dky. P\u0159i pr\u00e1ci s kapalinami nav\u00edc vznikaj\u00ed aerosoly, kter\u00e9 mohou proniknout do vnit\u0159n\u00edch \u010d\u00e1st\u00ed pipety. Zbytky vzorku se pak mohou p\u0159en\u00e9st p\u0159i dal\u0161\u00edm pipetov\u00e1n\u00ed, i kdy\u017e obsluha pou\u017eije novou \u0161pi\u010dku.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro\u010d je dekontaminace pipet d\u016fle\u017eit\u00e1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Zvl\u00e1\u0161\u0165 citliv\u00e9 jsou metody zalo\u017een\u00e9 na amplifikaci nukleov\u00fdch kyselin, nap\u0159\u00edklad PCR a qPCR. Pokud se do reakce dostane mal\u00e9 mno\u017estv\u00ed ciz\u00ed DNA nebo produktu z p\u0159edchoz\u00ed amplifikace, m\u016f\u017ee vzniknout sign\u00e1l v negativn\u00ed kontrole nebo fale\u0161n\u011b pozitivn\u00ed v\u00fdsledek. Laborato\u0159 pak m\u016f\u017ee muset dohledat zdroj kontaminace a zopakovat \u010d\u00e1st s\u00e9rie. Pravideln\u00e1 p\u00e9\u010de o pipety proto pom\u00e1h\u00e1 chr\u00e1nit v\u00fdsledky i omezovat spot\u0159ebu \u010dasu, reagenci\u00ed a vzork\u016f p\u0159i opakov\u00e1n\u00ed anal\u00fdz.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Jak nUVaClean\u2122 funguje<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>nUVaClean\u2122 od spole\u010dnosti MTC Bio<\/strong> je stoln\u00ed stojan s oza\u0159ovac\u00ed komorou pro a\u017e <strong>\u0161est jednokan\u00e1lov\u00fdch pipet<\/strong>. UV\u2011C lampa vyza\u0159uje sv\u011btlo o vlnov\u00e9 d\u00e9lce <strong>254 nm<\/strong> a reflektor jej sm\u011bruje kolem spodn\u00edch \u010d\u00e1st\u00ed pipet. UV\u2011C po\u0161kozuje nukleov\u00e9 kyseliny a na oz\u00e1\u0159en\u00fdch ploch\u00e1ch m\u016f\u017ee sn\u00ed\u017eit mno\u017estv\u00ed \u017eivotaschopn\u00fdch mikroorganism\u016f i mno\u017estv\u00ed DNA schopn\u00e9 amplifikace. <strong>Cyklus trv\u00e1 28 minut<\/strong> a po jeho skon\u010den\u00ed se p\u0159\u00edstroj automaticky vypne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobce v katalogu uv\u00e1d\u00ed zkou\u0161ku na pipet\u00e1ch kontaminovan\u00fdch bakteri\u00ed <em>Staphylococcus aureus<\/em>, p\u0159i n\u00ed\u017e sledoval pokles po\u010dtu \u017eivotaschopn\u00fdch bakteri\u00ed v pr\u016fb\u011bhu cyklu. V\u00fdsledek se vztahuje ke konkr\u00e9tn\u00edmu zku\u0161ebn\u00edmu uspo\u0159\u00e1d\u00e1n\u00ed. P\u0159i pou\u017e\u00edv\u00e1n\u00ed v laborato\u0159i z\u00e1vis\u00ed \u00fa\u010dinek UV\u2011C mimo jin\u00e9 na tom, zda z\u00e1\u0159en\u00ed dopad\u00e1 p\u0159\u00edmo na kontaminovan\u00e9 m\u00edsto. Zast\u00edn\u011bn\u00e9 plochy, vnit\u0159n\u00ed \u010d\u00e1sti pipety a m\u00edsta zakryt\u00e1 zaschl\u00fdmi zbytky vzorku proto mohou vy\u017eadovat samostatn\u00e9 o\u0161et\u0159en\u00ed podle n\u00e1vodu v\u00fdrobce pipety.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Jak p\u0159\u00edstroj za\u010dlenit do pr\u00e1ce laborato\u0159e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Praktick\u00e9 vyu\u017eit\u00ed m\u00e1 nUVaClean\u2122 nap\u0159\u00edklad na pracovi\u0161ti pro p\u0159\u00edpravu PCR, kde lze o\u0161et\u0159en\u00ed pipet za\u0159adit po skon\u010den\u00ed s\u00e9rie nebo sm\u011bny podle intern\u00edho postupu. Automatick\u00fd cyklus umo\u017e\u0148uje o\u0161et\u0159it n\u011bkolik pipet sou\u010dasn\u011b a zav\u00e9st jednotn\u00fd re\u017eim pro cel\u00fd t\u00fdm. V citliv\u00fdch aplikac\u00edch m\u00e1 UV\u2011C o\u0161et\u0159en\u00ed nejv\u011bt\u0161\u00ed smysl v kombinaci s vyhrazen\u00fdmi pipetami pro jednotliv\u00e9 pracovn\u00ed z\u00f3ny a s filtra\u010dn\u00edmi \u0161pi\u010dkami, kter\u00e9 omezuj\u00ed pr\u016fnik aerosol\u016f do pipety.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Viditeln\u00e9 zne\u010di\u0161t\u011bn\u00ed je t\u0159eba nejprve odstranit zp\u016fsobem, kter\u00fd doporu\u010duje v\u00fdrobce pipety. P\u0159i nas\u00e1t\u00ed kapaliny do t\u011bla pipety se postup \u0159\u00edd\u00ed n\u00e1vodem pro vnit\u0159n\u00ed \u010di\u0161t\u011bn\u00ed, dekontaminaci nebo servis konkr\u00e9tn\u00edho modelu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dekontaminace a kalibrace \u0159e\u0161\u00ed dv\u011b r\u016fzn\u00e1 rizika<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Dekontaminace omezuje p\u0159enos ne\u017e\u00e1douc\u00edho materi\u00e1lu mezi vzorky. Kalibrace ur\u010duje, jak\u00fd objem pipeta skute\u010dn\u011b d\u00e1vkuje.<\/strong> I spr\u00e1vn\u011b d\u00e1vkovan\u00fd objem m\u016f\u017ee obsahovat stopu p\u0159edchoz\u00edho vzorku. A \u010dist\u00e1 pipeta m\u016f\u017ee d\u00e1vkovat jin\u00fd objem, ne\u017e m\u00e1 nastaven\u00fd. P\u0159\u00ednos nUVaCleanu spo\u010d\u00edv\u00e1 v tom, \u017ee p\u00e9\u010di o oz\u00e1\u0159en\u00e9 \u010d\u00e1sti pipety lze za\u0159adit do b\u011b\u017en\u00e9ho provozu jako jednoduch\u00fd, opakovateln\u00fd krok.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Zdroje<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/mtcbiotech.com\/product\/nuvaclean-uv-pipette-sterilizer\/\">MTC Bio \u2013 technick\u00e9 \u00fadaje nUVaClean\u2122<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/mtcbiotech.com\/wp-content\/uploads\/2025\/05\/Catalog-A.5.2025.pdf\">MTC Bio \u2013 katalog a zkou\u0161ka \u00fa\u010dinnosti UV\u2011C<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.eppendorf.com\/product-media\/doc\/en\/116566_Userguide\/Eppendorf_Liquid-Handling_Userguide_024_Pipettes_Cleaning-Inspection-Pipettes.pdf\">Eppendorf \u2013 \u010di\u0161t\u011bn\u00ed a kontrola pipet<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.qiagen.com\/en-US\/resources\/download\/Protocols\/technical-note-for-the-identification-prevention-and-elimination-of-dna-and-rna-contaminations-en\">QIAGEN \u2013 prevence kontaminace DNA a RNA<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>V\u00fdm\u011bna \u0161pi\u010dky po ka\u017ed\u00e9m vzorku pat\u0159\u00ed k z\u00e1klad\u016fm spr\u00e1vn\u00e9ho pipetov\u00e1n\u00ed. Kontaminace se v\u0161ak m\u016f\u017ee zachytit i na samotn\u00e9 pipet\u011b, nap\u0159\u00edklad na ku\u017eelu pro nasazen\u00ed \u0161pi\u010dky. P\u0159i pr\u00e1ci s kapalinami nav\u00edc vznikaj\u00ed aerosoly, kter\u00e9 mohou proniknout do vnit\u0159n\u00edch \u010d\u00e1st\u00ed pipety. Zbytky vzorku se pak mohou p\u0159en\u00e9st p\u0159i dal\u0161\u00edm pipetov\u00e1n\u00ed, i kdy\u017e obsluha pou\u017eije novou \u0161pi\u010dku. Pro\u010d [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-817","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/posts\/817","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=817"}],"version-history":[{"count":1,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/posts\/817\/revisions"}],"predecessor-version":[{"id":819,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=\/wp\/v2\/posts\/817\/revisions\/819"}],"wp:attachment":[{"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=817"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=817"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kalibracepipet.cz\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=817"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}